Dish Capacity: 8 four-well culture dishes / 8 single-well round culture dishes (60 mm) / 20 single-well round culture dishes (35 mm)
Altitude: ≤ 2000m
Power Supply: AC 220V, 50Hz
Rated Power:120VA
Operating Ambient Temperature: The set control temperature should be at least 5°C higher than the ambient temperature.
Operating Ambient Humidity: Relative humidity: 5% to 90%, non-condensing gas
Gas: Premixed gas
Temperature Control Range: +22.0°C to +42.0°C
Temperature Control Accuracy: ±0.1°C (when temperature is set to 37.0°C; for other set ranges, control accuracy is ±0.2°C)
Temperature Fluctuation Range: ±0.1°C (when temperature is set to 37.0°C; for other set ranges, control fluctuation is ±0.2°C)
Internal Temperature Uniformity:<±0.2°C (when temperature is set to 37.0°C)
Temperature Recovery Time: 60 seconds
Flow Rate Control Range: +15 mL/min to 35 mL/min (adjustable in 5 mL/min increments)
Flow Rate Control Accuracy: ±2 mL/min
Flow Rate Fluctuation Range: ±4 mL/min
Recovery (Flushing) Flow Rate: 170 mL/min to 190 mL/min per chamber
Humidification Performance: ≥75%
Humidity Recovery Time: ≤4h
Water Level Monitoring: Software alert when 7 days of water remaining / Software alert when 3 days of water remaining
External Dimensions: 42cm × 27.5cm × 19cm (W × D × H)
Instrument Weight: 17.9KG 
Battery:1.5–2h
Weight: 17.9 (kg)
Size: 42 * 27.5 * 19 (cm)
Technical SpecificationsPerformance Indicators
Dish Capacity: 8 four-well culture dishes / 8 single-well round culture dishes (60 mm) / 20 single-well round culture dishes (35 mm)
Altitude: ≤ 2000m
Power Supply: AC 220V, 50Hz
Rated Power:120VA
Operating Ambient Temperature: The set control temperature should be at least 5°C higher than the ambient temperature.
Operating Ambient Humidity: Relative humidity: 5% to 90%, non-condensing gas
Gas: Premixed gas
Temperature Control Range: +22.0°C to +42.0°C
Temperature Control Accuracy: ±0.1°C (when temperature is set to 37.0°C; for other set ranges, control accuracy is ±0.2°C)
Temperature Fluctuation Range: ±0.1°C (when temperature is set to 37.0°C; for other set ranges, control fluctuation is ±0.2°C)
Internal Temperature Uniformity:<±0.2°C (when temperature is set to 37.0°C)
Temperature Recovery Time: 60 seconds
Flow Rate Control Range: +15 mL/min to 35 mL/min (adjustable in 5 mL/min increments)
Flow Rate Control Accuracy: ±2 mL/min
Flow Rate Fluctuation Range: ±4 mL/min
Recovery (Flushing) Flow Rate: 170 mL/min to 190 mL/min per chamber
Humidification Performance: ≥75%
Humidity Recovery Time: ≤4h
Water Level Monitoring: Software alert when 7 days of water remaining / Software alert when 3 days of water remaining
External Dimensions: 42cm × 27.5cm × 19cm (W × D × H)